Pres 2 Pure

PERSONAL

MOBILE

WATER

FILTRATION SYSTEM

Protect your family with clean, safe, great tasting drinking water.


Proprietary Filter Removes & Reduces

The rate of adsorption is determined by the physical and chemical characteristic of the quality and volume of carbon used. The flow rate or time of exposure through the filter have been calculated to yield the greatest volume of pollutant and contaminant removal.

Pres2Pure also incorporates other exclusive medias that are impregnated into the micro-porous filter for the removal of pollutants such as lead, cadmium, zinc, mercury, and copper.

    Aqua Vision International’s Pres 2 PureTM Portable Water Filter testing results:

This testing information is based on an average of the four laboratories listed below. It should be understood that the results were obtained by using EPA, ANSI and NSF protocol and methodology. The individual tests are available upon request. DESCRIPTION OF TESTING METHODS. EPA METHOD 60B, 524.2, 504, 505, 507 515.1, 531.1, 624 from EPA publication EPS 600/4-79-020, rev. 3/83 and ANSI/NSF Standard 53. All test results are within the last physical year 1996-97..


ORGANIC TESTING: Volatile Organic Compounds - Organochlorine Pesticides


Analyte
Prefilter Concentration
Units
% Reduction
Bromodichloromethane*
250
ug/l
>99.73
Bromoform*
250
ug/l
>99.46
Acetone
250
ug/l
>96.20
Benzene
250
ug/l
>99.50
Chloroform*
250
ug/l
>99.50
Chlorobenzene
250
ug/l
>99.20
Dibromochloromethane*
250
ug/l
>99.46
Carbon Tetrachloride
250
ug/l
>99.63
1,2-1,3-1,4- Dichlorobenzenes
250
ug/l
>99.71
1,1-1,2- Dichloroethane
250
ug/l
>99.80
1,1-1,2- Dichloroethylene
250
ug/l
>99.80
Ethylbenzene
250
ug/l
>99.53
Styrene
250
ug/l
>99.43
MTBE
250
ug/l
>99.80
1,1,1-1,1,2- Trichlorothane
250
ug/l
>99.76
Trichloroethylene
250
ug/l
>99.76
Toluene
250
ug/l
>99.80
Total Xylenes
250
ug/l
>99.50
Gamma BHC (Lindane)
10
ug/l
>97.75
Heptachlor
10
ug/l
>98.56
Endrin
10
ug/l
>99.00
Ethylene Dibromide (EDB)
10
ug/l
>95.00
Dibromochloroprepane (DBCP)
10
ug/l
>98.00
Heptachlor-Epoxide
10
ug/l
>98.7
4,4- DDD and DDT
10
ug/l
>98.8
Methoxychlor
10
ug/l
>94.6
PCB's Arochlor-1260
20
ug/l
>94.5

INORGANIC TESTING: MBAS analysis - Trace Metals - Turbidity - Radiological


Analyte
Prefilter Concentration
Units
% Reduction
Aluminum
2
mg/l
>90.0
Arsenic
100
mg/l
>17
Cadmium
100
mg/l
>85.75
Chlorine Residual
1.2
mg/l
>94.1
Chromium
100
mg/l
>93.72
Copper
100
mg/l
>98.50
Flouride
2.5
mg/l
>47.20
Lead
100
mg/l
>98.00
Mercury
100
mg/l
>99.25
Nitrate & Nitrite
19.065
mg/l
>88.43
Radon 222
540
pci/l
>99.0
Total Suspended Solids
486
mg/l
>99.0
Turbidity
20
NTU
>85.6

MICROBIOLOGICAL TESTING


Analyte
Prefilter Concentration
Units
% Reduction
Giardi
10^6/L
na
>99.99
Cryptosporidium
10^6/L
na
>99.9
E-Coli
na
na
>99.

For ordering information or dealer inquiries

Send E-mail Here